✉ info@eieinstruments.com
Home/Shop by Category/Civil Engineering Testing Instruments/Concrete Testing Instruments
Four-cell Rcpt With Temperature Sensing Using Daq System – Without Accessories

Four-cell Rcpt With Temperature Sensing Using Daq System – Without Accessories

Model Number : EIE-017-4.1

Rapid Chloride Ion Permeability Test apparatus as per ASTM-1202-05

As per ASTM 1202 - 05 including :
  • Each RCPT cell will be made up of transparent acrylic material of 150 * 150mm* 50mm thick as per ASTMC 1202.
  • It will hold the concrete specimen of 100mm diameter 50mm thick.
  • It will be provided with rubber gasket and washers for achieving leak proof.
  • Stainless steel bolts with washers and nuts will be provided to hold the specimen rigidly.
  • The power supply will be applied to each cell through banana sockets and the current will be distributed through the brass mesh.
  • Each cell will be provided with openings in top for pouring chemicals and the temperature sensors. The openings can be closed with lids.
  • The volume of chemicals within the chamber shall be 250ml.
  • No. Of cells : Four cells
  • Power supply : 0-99.9 volt DC adjustable provide supply to Four cells
  • Protections : fuse for each cell
  • Indications : digital voltmeter three digit seven segment LED display
  • Cells details : as per the specifications
  • Dc supply can be varied from 0-99.9 volts continuously
  • DC supply should be provided to all the four channels simultaneously and the current flow through each cell will be separately monitored.
  • Flexible cables with the banana type pins will be provided for all the cells to establish the connection with the apparatus.
  • Temperature of each cell also monitored and recorded.
Data acquisition Processing system and software:
  • DC voltage in 0-99.9volt, current in 999.9 milliamp. and the temperature of chemical solutions in 99.9 deg Centigrade (maximum values)
  • LCD displays indicate all the parameters continuously. All the data are transmitted to the computer simultaneously.
  • Record Interval time set : 0-99hr, 0-99min and 0-99 Sec, Total log time set : 0-99hr, 0-99min and 0-99 Sec.
  • The set values are settable through key pad switches provided
  • Totally eight parameters, four numbers of cell current and four numbers of temperature of the cell chemicals are displayed
  • All the acquired data are transferred to the PC through RS232 output and through USB
  • The monitor display the present current reading as well as the cumulative current reading.
  • At the end of test, quartz buzzer is activated and the PC saves the readings in a separate file.
  • For graphical display software is provided.
Supplied Complete with.....
  1. Plexiglass chambers with conductive brass mesh, terminals and Steel bolts - 4 pairs
  2. DC Constant voltage power supply (220 V) cum DAQ unit with 4 channels. - 1 No.
  3. 250 mm vacuum desiccators. - 1 No.
  4. Vacuum pump - 1 No.
  5. Moisture trap with vacuum gauge - 1 No.
  6. Elastomeric Rubber Moulds for cylindrical specimens - 4 No.
  7. Thermocouples - 4 No.
  8. Consumables - good for 1 doz. tests
  9. RTV sealant + gun - 1 No.
  10. Acrylic sealer , Brush - 1 each
  11. NaCl, NaOH - 1 each
  12. Mould Release - 1 No.

Coming Soon...

Coming Soon...

Coming Soon...